fbpx

R1700 XE Underground Battery-Electric LHD Loader

The Cat® R1700 XE 15-tonne (16.5 ton) payload battery electric LHD is designed to deliver superior productivity, with the benefits of no engine heat or exhaust emissions. With key performance metrics matching R1700 diesel LHD, the R1700 XE features fast charging by means of the MEC500 mobile equipment charger with stringent safety features.

Rated Power - Peak 250 kW
Ability of Regenerative Braking Yes
Cooling Method Liquid
Efficiency 95%
Motor Type Switched Reluctance
Rated Power - Nominal 220 kW
Rated Torque (peak, nominal = @ 12 km/h [7.5 mph] and nominal power) 3200 N·m/660 N·m (2360 lbf-ft/443 lbf-ft)
Service Interval 12,000-13,000 hours

Rated Payload 15000 kg
Breakout Force - Lift and Tilt 24190 kg
Static Tipping Load - Straight Ahead - Lift Arms Horizontal 49203 kg
Static Tipping Load - Full Turn - Lift Arms Horizontal 40649 kg
Bucket Capacities 5.7-7.5 m³ (7.5-9.8 yd³)
Operating Mass 48743 kg
Ride Control Yes
Shipping Weight 51918 kg

Lower, Empty, Float Down 2.9 s
Total Cycle Time 13.2 s
Dump 3.3 s
Raise 6.8 s

Lift/Tilt System - Circuit Electro – Hydraulic, Positive Flow Control, Flow Sharing
Lift Cylinder - Bore 170 mm
Lift Cylinder - Stroke 830 mm
Lift/Tilt System - Pump Variable Flow Piston/Hydraulic Load Sense
Maximum Flow 297 l/min
Relief Valve Setting - Main 34000 kPa
Tilt Cylinder - Bore 210 mm
Tilt Cylinder - Stroke 564 mm

Cooling Method Liquid
Efficiency 96%
Motor Type Switched Reluctance
Rated Power (peak, nominal) 226 kW
Rated Torque (peak, nominal = 1,600 equivalent rpm) 600 N·m/531 N·m (443 lbf-ft/392 lbf-ft)
Service Interval 12,000-13,000 hours

Battery Chemistry Li-lon
Battery Cooling Method Chilled Liquid (Extended Life Coolant)
Battery Monitoring With integrated Caterpillar controls systems
Charging Current, Voltage 1160A (output), 820VDC
Charging Method Ultra Fast Charge Onboard
Charging Rate Up to 4C (matched with MEC500 chargers)
Maximum Charging Rate 840 kW (two MEC500 chargers)
Minimum Charging Rate 500 kW
On Board Fast Charging Charge time (0-100%) Less than 20 minutes (two MEC500 in parallel); Less than 30 minutes (one MEC500)
Operating Temperature Limits (ambient) 50° C/–20° C (122° F/-4° F)
Pack Energy Capacity - Total 213 kWh
Pack Voltage - Nominal 715 V

0% Grade - Loaded 18 km/h
0% Grade - Unloaded 18 km/h
10% Grade - Loaded 8.6 km/h
10% Grade - Unloaded 11.1 km/h
15% Grade - Loaded 6.1 km/h
15% Grade - Unloaded 7.9 km/h
20% Grade - Loaded 4.8 km/h
20% Grade - Unloaded 6.2 km/h
5% Grade - Loaded 14.8 km/h
5% Grade - Unloaded 18 km/h

Component Ratings IP67, IP69K
Cooling Method Liquid (coolant)
Inverter Rating 350A (nominal DC), 715VDC
Service Interval 12,000-13,000 hours